XXX-MIB DEFINITIONS ::= BEGIN   

IMPORTS
			MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, Gauge32,
			Integer32,Counter32,enterprises, 
			NOTIFICATION-TYPE                        FROM SNMPv2-SMI
			DisplayString                            FROM SNMPv2-TC;

company		MODULE-IDENTITY
			LAST-UPDATED  "200903050000Z"
			ORGANIZATION  "CData"
			CONTACT-INFO  "www.cdatatec.com"
			DESCRIPTION   "Media Converter NMS SNMP mib file"
			REVISION      "200903050000Z"
			DESCRIPTION   "1G MC supported"
			::= { enterprises 34592 }

ipProduct	OBJECT-IDENTITY 
			STATUS          current
			DESCRIPTION     "IP product line"
			::= {company 1}   

height2HU		OBJECT IDENTIFIER ::= {ipProduct  1}

systemMIB	OBJECT IDENTIFIER ::= {height2HU  1}

alarmMIB		OBJECT IDENTIFIER ::= {height2HU  2}

-- [ShelfInfo] --
shelfNum		OBJECT-TYPE
				SYNTAX			INTEGER (1..4)
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION     "The number of shelf in current system"
				::= { systemMIB 1 } 	

shelfTable		OBJECT-TYPE
				SYNTAX			SEQUENCE OF ShelfEntry
				MAX-ACCESS		not-accessible
				STATUS			current
				DESCRIPTION     "Shelf table"
				::= { systemMIB 2 }  
						
shelfEntry  	OBJECT-TYPE
				SYNTAX			ShelfEntry
				MAX-ACCESS		not-accessible
				STATUS			current
				DESCRIPTION     "Shelf entry definition"
				INDEX			{ shelfName }
				::= { shelfTable 1 }
						
ShelfEntry		::= SEQUENCE {
					shelfName			INTEGER,
					psuA				INTEGER,     
					psuB				INTEGER,  
					volA				INTEGER,     
					volB				INTEGER,  
					fan					INTEGER, 
					temperature			INTEGER,
					coCardNum			INTEGER, 
					rmtCardNum			INTEGER 
				}    
						
shelfName		OBJECT-TYPE
				SYNTAX			INTEGER {master(1),slave_1(2),slave_2(3),slave_3(4)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION     "Shelf name"
				::= { shelfEntry 1 }

psuA			OBJECT-TYPE
				SYNTAX	INTEGER {on(1),off(2),nc(3)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION     "The status fan A of current shelf"
				::= { shelfEntry 2 }  

psuB			OBJECT-TYPE
				SYNTAX	INTEGER {on(1),off(2),nc(3)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION     "The status psu B of current shelf"
				::= { shelfEntry 3 }

volA			OBJECT-TYPE
				SYNTAX	INTEGER {normal(1),abnormal(2),nc(3)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION     "The voltage status of psuA of current shelf"
				::= { shelfEntry 4 }  

volB			OBJECT-TYPE
				SYNTAX	INTEGER {normal(1),abnormal(2),nc(3)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION     "The voltage status of psuB of current shelf"
				::= { shelfEntry 5 }
				
fan				OBJECT-TYPE
				SYNTAX	INTEGER {on(1),off(2),nc(3)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION     "The status fan A of current shelf"
				::= { shelfEntry 6 } 
															
temperature     OBJECT-TYPE
				SYNTAX			INTEGER
				UNITS			" °C"
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION     "The temperature status of current shelf"
				::= { shelfEntry 7 } 

coCardNum		OBJECT-TYPE
				SYNTAX			INTEGER (0..16)   
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION     "The number of center card inserting of current shelf"
				::= { shelfEntry 8 } 
						
rmtCardNum		OBJECT-TYPE
				SYNTAX			INTEGER (0..16)
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION     "The number of remote card inserting of current shelf"
				::= { shelfEntry 9 }						
														
-- [Slot Objects] --
                
slotObjects		OBJECT IDENTIFIER  ::= {systemMIB 3}
						  
slotTable	    OBJECT-TYPE
				SYNTAX			SEQUENCE OF SlotEntry
				MAX-ACCESS		not-accessible
				STATUS			current
				DESCRIPTION     "Sparse table containing one entry for each slot in exist
                      			 chassis in the system, indexed by shelfIdx and slotIdx."
				::= { slotObjects 1 }						  

slotEntry		OBJECT-TYPE
				SYNTAX			SlotEntry
				MAX-ACCESS		not-accessible
				STATUS			current
				DESCRIPTION     "in this table ,user can find the converter module's type inserted
		                       in  the system's slot.then you can get the detail information about
		                       the specified type in the cardObjects table"
				INDEX			{ shelfIdx, slotIdx }										  
				::= { slotTable 1 }	
						
SlotEntry ::=	SEQUENCE {
					shelfIdx			INTEGER,
					slotIdx				INTEGER,
					coCardType			INTEGER,
					coCardDesc			DisplayString,															
					rmtCardType			INTEGER,
					rmtCardDesc			DisplayString
				}											  

shelfIdx		OBJECT-TYPE
				SYNTAX			INTEGER  {master(1),slave_1(2),slave_2(3),slave_3(4)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION     "Chassis index - 1 = master management module,
                                 2-4 = slave management module"
				::= { slotEntry 1 }

slotIdx			OBJECT-TYPE
				SYNTAX			INTEGER {slot01(1),slot02(2),slot03(3),slot04(4),
				                         slot05(5),slot06(6),slot07(7),slot08(8),
				                         slot09(9),slot10(10),slot11(11),slot12(12),
				                         slot13(13),slot14(14),slot15(15),slot16(16), slot17(17)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION     "chassis's slot,whitch is a index in this table"
				::= { slotEntry  2 }

coCardType		OBJECT-TYPE
				SYNTAX			INTEGER {no_card(0),ip113s(1),ip113f(2),mc_1g_e2o(3),mc_1g_o2o(4),fr600f-mm(100),fr600f-ms(101),not-support(102)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION     "local card's type inserted in the chassis"
				::= { slotEntry  3 }

coCardDesc		OBJECT-TYPE
				SYNTAX			DisplayString
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"local card's description"
				::= { slotEntry 4 }
						
rmtCardType		OBJECT-TYPE
				SYNTAX			INTEGER {no_card(0),ip113sr(1),ip113f(2),mc_1g_e2o(3),mc_1g_o2o(4),fr600f-mm(100),fr600f-ms(101),not-support(102)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION     "remote card's type connect with the local converter"
				::= { slotEntry  5 }							 
							
rmtCardDesc		OBJECT-TYPE
				SYNTAX			DisplayString
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"remote card's description"
				::= { slotEntry 6 }
							
-- [Card Objects] --
cardObjects		OBJECT IDENTIFIER ::= {systemMIB 4}
                  
-- --[NMU Objects] --                  
nmuObjects		OBJECT IDENTIFIER ::= {cardObjects 1}
nmuConfig		OBJECT IDENTIFIER ::= {nmuObjects 1}

nmuType			OBJECT-TYPE
				SYNTAX			INTEGER {fr600f-mm(100),fr600f-ms(101),not-support(102)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"The type of NMU (network management unit)"
				::= { nmuConfig 1 } 
						
ipaddr			OBJECT-TYPE
				SYNTAX			IpAddress
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION 	"The ethernet IP address of NMU (network management unit)"
				::= { nmuConfig 2 }

subnet			OBJECT-TYPE
				SYNTAX			IpAddress
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"The etherent mask address of NMU (network management unit)"
				::= { nmuConfig 3 }

gateway 		OBJECT-TYPE
				SYNTAX 			IpAddress
				MAX-ACCESS 		read-only
				STATUS			current
				DESCRIPTION		"The ethernet gateway address of NMU (network management unit)"
				::= { nmuConfig 4 }   
        
sysContact		OBJECT-TYPE
				SYNTAX			DisplayString
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"Mirror of the system.sysContact.0"
				::= { nmuConfig 5 }

sysName			OBJECT-TYPE
				SYNTAX			DisplayString
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"Mirror of the system.sysName.0"
				::= { nmuConfig 6 }

sysLocation		OBJECT-TYPE
				SYNTAX			DisplayString
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"Mirror of the system.sysLocation.0"
				::= { nmuConfig 7 }

trapHost1		OBJECT-TYPE
				SYNTAX			IpAddress
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"The first host's IP address used to receive trap messages,
								when set 0 it simply delete this entry. This applies to the trap host 2~4 below as well."
				::= { nmuConfig 8 }

trapHost2		OBJECT-TYPE
				SYNTAX			IpAddress
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"The second host's IP address used to receive trap messages"
				::= { nmuConfig 9 }

trapHost3		OBJECT-TYPE
				SYNTAX			IpAddress
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"The third host's IP address used to receive trap messages"
				::= { nmuConfig 10 }
						
trapHost4		OBJECT-TYPE
				SYNTAX			IpAddress
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"The fourth host's IP address used to receive trap messages"
				::= { nmuConfig 11 }																							      
                
-- --[MC Configuration table] --
mcCmObjects		OBJECT IDENTIFIER ::= {cardObjects 2}

mcCmTable		OBJECT-TYPE
				SYNTAX			SEQUENCE OF McCmEntry
				MAX-ACCESS		not-accessible
				STATUS			current
				DESCRIPTION    "MC Configuration table"
				::= { mcCmObjects 1 }			          

mcCmEntry		OBJECT-TYPE
				SYNTAX			McCmEntry
				MAX-ACCESS		not-accessible
				STATUS			current
				DESCRIPTION		"MC Configuration entry definition"
				INDEX			{ mcShelfIdx, mcCardIdx }										  
						::= { mcCmTable 1 }
						
McCmEntry ::=		SEQUENCE {
					mcShelfIdx			INTEGER,
					mcCardIdx			INTEGER,

					mcType				INTEGER,
					mcTransceiverMode	INTEGER,
					mcTransceiverDist	INTEGER,
					mcPortState			INTEGER,
					mcTransmitMode		INTEGER,
					mcCurWorkMode		INTEGER,
					mcCfgWorkMode		INTEGER,
					mcLFPCfg			INTEGER,
					mcUpStream			Gauge32,
					mcDownStream		Gauge32,
					mcTxlink			INTEGER,
					mcFxlink			INTEGER,
					mcHWLFP				INTEGER,
					mcHWTransmitMode	INTEGER,
					mcHWWorkMode		INTEGER,
					mcHWRmtCtrlMode		INTEGER,
					mcNtwSfpExist		INTEGER,  -- for 1G E2O or O2O card
					mcAccSfpExist		INTEGER,  -- for 1G O2O card only
					mcUtility			INTEGER,
					
					mcRmtDetect			INTEGER,
					mcRmtType			INTEGER,
					mcRmtTransmitMode	INTEGER,
					mcRmtCurWorkMode	INTEGER,
					mcRmtCfgWorkMode	INTEGER,
					mcRmtLFP			INTEGER,
					mcRmtTxlink			INTEGER,
					mcRmtHWLFP			INTEGER,
					mcRmtHWTransmitMode	INTEGER,
					mcRmtHWWorkMode		INTEGER,
					mcRmtLoopback		INTEGER,
					mcRmtPwrDown		INTEGER,
					mcRmtAccSfpExist	INTEGER, -- for 1G O2O card only. NtwSfp is always exist when remore detected.
					mcRmtUtility		INTEGER				
				}						
										  				

mcShelfIdx		OBJECT-TYPE
				SYNTAX			INTEGER  {master(1),slave1(2),slave2(3),slave3(4)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Shelf index"
				::= { mcCmEntry 1 }

mcCardIdx		OBJECT-TYPE
				SYNTAX			INTEGER {card01(1),card02(2),card03(3),card04(4),
				                         card05(5),card06(6),card07(7),card08(8),
				                         card09(9),card10(10),card11(11),card12(12),
				                         card13(13),card14(14),card15(15),card16(16)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Card index"                                                        
				::= { mcCmEntry 2 }     
						
mcType			OBJECT-TYPE
				SYNTAX			INTEGER {ip113s(1),ip113f(2),mc_1g_e2o(3),mc_1g_o2o(4),not-support(5)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Center card's type"
				::= { mcCmEntry 3 }                            
						         
mcTransceiverMode	OBJECT-TYPE
				SYNTAX			INTEGER {bidi(1),duplex_fiber(2),sfp(3),not-support(4)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Center card's optical transceiver mode.
								100M card support bidi/duplex_fiber; 1G card support bidi/duplex_fiber/sfp.
								Once sfp is given, the following mcTransceiverDist should be ignored."
				::= { mcCmEntry 4 }             

mcTransceiverDist	OBJECT-TYPE
				SYNTAX			INTEGER (1..120)
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Center card's optical transceiver distance, 
								1 means 550m for duplex_fiber mode in case of 1G card,
								otherwise it represents the real distance (unit of km)."
				::= { mcCmEntry 5 } 
						         
mcPortState		OBJECT-TYPE
				SYNTAX			INTEGER {locked(1),unlocked(2),not-support(3)}
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"Center card's port status, locked or unlocked"
				::= { mcCmEntry 6 }     
				
mcTransmitMode	OBJECT-TYPE
				SYNTAX			INTEGER {cut-through(1),store-forward(2),not-support(3)}
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"Center card's transmmit mode"
				::= { mcCmEntry 7 } 

mcCurWorkMode	OBJECT-TYPE
				SYNTAX			INTEGER { -- mAuto(1),
										 m100-full(2),
				                         m100-half(3),
				                         m10-full(4),
				                         m10-half(5), 
				                         m1G-full(6),
				                         not-support(7)}
				MAX-ACCESS		read-only
				STATUS			mandatory
				DESCRIPTION		"Center card's current work mode"
				::= { mcCmEntry 8 } 						
						
mcCfgWorkMode	OBJECT-TYPE
				SYNTAX			INTEGER {mAuto(1),
										 m100-full(2),
				                         m100-half(3),
				                         m10-full(4),
				                         m10-half(5), 
				                         m1G-full(6),
				                         not-support(7)}
				MAX-ACCESS		read-write
				STATUS			mandatory
				DESCRIPTION		"Center card's configurable work mode"
				::= { mcCmEntry 9 } 						
						     
mcLFPCfg		OBJECT-TYPE
				SYNTAX			INTEGER {enable(1),disable(2),not-support(3)}
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"Remote fault detect function, valid only on center MC card"
				::= { mcCmEntry 10 }  
						
mcUpStream		OBJECT-TYPE
				SYNTAX			Gauge32  
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"Center card's up stream of MC"
				::= { mcCmEntry 11}

mcDownStream	OBJECT-TYPE
				SYNTAX			Gauge32 
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"Center card's down stream of MC"                                                   
				::= { mcCmEntry 12 }						 
						
mcTxlink		OBJECT-TYPE
				SYNTAX			INTEGER  {up(1),down(2),not-support(3)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Center card's electrical port's link status"  
				::= { mcCmEntry 13 }
						
mcFxlink		OBJECT-TYPE
				SYNTAX			INTEGER  {up(1),down(2),not-support(3)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Center card's optical port's link status"
				::= { mcCmEntry 14 }
                                   
mcHWLFP			OBJECT-TYPE
				SYNTAX			INTEGER  {enable(1),disable(2),not-support(3)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Center card's HW LFP, not applicable for 1G card"
				::= { mcCmEntry 15 }

mcHWTransmitMode	OBJECT-TYPE
				SYNTAX			INTEGER  {cut-through(1),store-forward(2),not-support(3)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Center card's HW transmit mode, not applicable for 1G card"
				::= { mcCmEntry 16 }
                                   
mcHWWorkMode	OBJECT-TYPE
				SYNTAX			INTEGER {mAuto(1),
										 m100-full(2),
				                         m100-half(3),
				                         m10-full(4),
				                         m10-half(5), 
				                         m1G-full(6),
				                         not-support(7)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Center card's HW work mode, not applicable for 1G card"
				::= { mcCmEntry 17 }
                   
mcHWRmtCtrlMode OBJECT-TYPE
				SYNTAX			INTEGER {enable(1),disable(2),not-support(3)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Center card's HW remote control mode (only valid for local card).
								the disable mode indicates that all SET operations must be prohibited"
				::= { mcCmEntry 18 }
                                   
mcNtwSfpExist   OBJECT-TYPE
				SYNTAX			INTEGER  {inserted(1),removed(2),na(3),not-support(4)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Center 1G card's Network SFP indication"
				::= { mcCmEntry 19 }
                                   
mcAccSfpExist   OBJECT-TYPE
				SYNTAX			INTEGER  {inserted(1),removed(2),na(3),not-support(4)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Center 1G card's Access SFP indication, applicable only for O2O type"
				::= { mcCmEntry 20 }

mcUtility		OBJECT-TYPE
				SYNTAX			INTEGER  {idle(1),reset(2),default(3),set2hw(4),not-support(5)}
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"reset, default to factory, set to HW word, etc..."
				::= { mcCmEntry 21 }
                                   
mcRmtDetect		OBJECT-TYPE
				SYNTAX			INTEGER  {no_remote(0),yes(1),not-support(2)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"An identifier to indicate if there is a remote MC currently connecting to system or not"
				::= { mcCmEntry 22 }    
						
mcRmtType		OBJECT-TYPE
				SYNTAX			INTEGER {no_card(0),ip113sr(1),ip113f(2),mc_1g_e2or(3),mc_1g_o2or(4),not-support(5)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Remote card's type"
				::= { mcCmEntry 23 }

mcRmtTransmitMode	OBJECT-TYPE
				SYNTAX			INTEGER {no_card(0),cut-through(1),store-forward(2),not-support(3)}
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"Remote card's transmmit mode"
				::= { mcCmEntry 24 } 
				
mcRmtCurWorkMode	OBJECT-TYPE
				SYNTAX			INTEGER {no_card(0),
										 -- mAuto(1),
										 m100-full(2),
				                         m100-half(3),
				                         m10-full(4),
				                         m10-half(5), 
				                         m1G-full(6),
				                         not-support(7)}
				MAX-ACCESS		read-only
				STATUS			mandatory
				DESCRIPTION		"Remote card's current work mode"
				::= { mcCmEntry 25 } 						
						
mcRmtCfgWorkMode	OBJECT-TYPE
				SYNTAX			INTEGER {no_card(0),
										 mAuto(1),
										 m100-full(2),
				                         m100-half(3),
				                         m10-full(4),
				                         m10-half(5), 
				                         m1G-full(6),
				                         not-support(7)}
				MAX-ACCESS		read-write
				STATUS			mandatory
				DESCRIPTION		"Remote card's configurable work mode"
				::= { mcCmEntry 26 } 						

mcRmtLFP		OBJECT-TYPE
				SYNTAX			INTEGER  {no_card(0),enable(1),disable(2),not-support(3)}
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"Remote card's LFP lamp state"                                                   
				::= { mcCmEntry 27 }
						
mcRmtTxlink		OBJECT-TYPE
				SYNTAX			INTEGER  {no_card(0),up(1),down(2),not-support(3)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Remote card's electrial port status"                                                   
				::= { mcCmEntry 28 }   

mcRmtHWLFP		OBJECT-TYPE
				SYNTAX			INTEGER  {no_card(0),enable(1),disable(2),not-support(3)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Remote card's HW LFP, not applicable for 1G card"
				::= { mcCmEntry 29 }

mcRmtHWTransmitMode	OBJECT-TYPE
				SYNTAX			INTEGER  {no_card(0),cut-through(1),store-forward(2),not-support(3)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Remote card's HW transmit mode, not applicable for 1G card"
				::= { mcCmEntry 30 }
                                   
mcRmtHWWorkMode	OBJECT-TYPE
				SYNTAX			INTEGER {no_card(0),
										 mAuto(1),
										 m100-full(2),
				                         m100-half(3),
				                         m10-full(4),
				                         m10-half(5), 
				                         m1G-full(6),
				                         not-support(7)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Remote card's HW work mode, not applicable for 1G card"
				::= { mcCmEntry 31 }

mcRmtLoopback	OBJECT-TYPE
				SYNTAX			INTEGER  {no_card(0),enable(1),disable(2),not-support(3)}
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"Remote card's HW Loopback state"
				::= { mcCmEntry 32 }

mcRmtPwrDown    OBJECT-TYPE
				SYNTAX			INTEGER  {no_card(0),powerdown(1),normal(2),not-support(3)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Remote card's power down state"
				::= { mcCmEntry 33 }

mcRmtAccSfpExist   OBJECT-TYPE
				SYNTAX			INTEGER  {no_card(0),inserted(1),removed(2),na(3),support(4)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"Remote 1G card's Access SFP indication, applicable only for O2O type"
				::= { mcCmEntry 34 }

mcRmtUtility	OBJECT-TYPE
				SYNTAX			INTEGER  {no_card(0),idle(1),reset(2),default(3),set2hw(4),not-support(5)}
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"Rmote cards's reset, default to factory, set to HW word, etc..."
				::= { mcCmEntry 35 }

-- --[MC 1G card Specific CM table] --   
mcCm1gSpecificObjects	OBJECT IDENTIFIER ::= {mcCmObjects 2}

-- -- --[MC 1G card IP table] --  
mcCm1gIpObjects		OBJECT IDENTIFIER ::= {mcCm1gSpecificObjects 1}

mcCm1gIpTable	OBJECT-TYPE
				SYNTAX			SEQUENCE OF McCm1gIpEntry
				MAX-ACCESS		not-accessible
				STATUS			current
				DESCRIPTION    "MC 1G Ip address table"
				::= { mcCm1gIpObjects 1 }			          

mcCm1gIpEntry	OBJECT-TYPE
				SYNTAX			McCm1gIpEntry
				MAX-ACCESS		not-accessible
				STATUS			current
				DESCRIPTION		"MC 1G Ip address entry definition"
				INDEX			{ mcShelfIdx,mcCardIdx,mcLoOrRmtFg }										  
						::= { mcCm1gIpTable 1 }
										
McCm1gIpEntry ::=	SEQUENCE {
					mcLoOrRmtFg		INTEGER,
					mcIpAddr		IpAddress
				}
										
mcLoOrRmtFg		OBJECT-TYPE
				SYNTAX			INTEGER  {local(1),remote(2)}
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"location index, local or remote"
				::= { mcCm1gIpEntry 1 }
										  				
mcIpAddr		OBJECT-TYPE
				SYNTAX			IpAddress
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"The Ip address of the node"
				::= { mcCm1gIpEntry 2 }          

-- -- --[MC 1G card SFP table] --  
mcCm1gSfpObjects	OBJECT IDENTIFIER ::= {mcCm1gSpecificObjects 2}

mcCm1gSfpTable	OBJECT-TYPE
				SYNTAX			SEQUENCE OF McCm1gSfpEntry
				MAX-ACCESS		not-accessible
				STATUS			current
				DESCRIPTION    "MC 1G SFP table"
				::= { mcCm1gSfpObjects 1 }			          

mcCm1gSfpEntry	OBJECT-TYPE
				SYNTAX			McCm1gSfpEntry
				MAX-ACCESS		not-accessible
				STATUS			current
				DESCRIPTION		"MC 1G SFP entry definition"
				INDEX			{ mcShelfIdx,mcCardIdx,mcLoOrRmtFg }										  
						::= { mcCm1gSfpTable 1 }
										
McCm1gSfpEntry ::=	SEQUENCE {
					getSfpCmd			INTEGER,
					sfpCompliance		INTEGER,
					sfpConnector		INTEGER,
					sfpTransCode		INTEGER,
					sfpSmLength			INTEGER,
					sfpMmLength			INTEGER,
					sfpCopperLength		INTEGER,
					sfpBrSpeed			INTEGER,
					sfpWavelength		INTEGER,
					sfpTemperature		INTEGER,
					sfpTranPower		INTEGER,
					sfpRecvPower		INTEGER,
					sfpVoltage			INTEGER
				}				
						
getSfpCmd		OBJECT-TYPE
				SYNTAX			INTEGER {na(0),local(1),remote(2)}
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"This command will get the updated sfp information. 
								Please send this command prior to getting the following params,
								otherwise the history sfp information will be sent back."
				::= { mcCm1gSfpEntry 1 }

sfpCompliance	OBJECT-TYPE
				SYNTAX			INTEGER
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"SFP compliance (one byte)
								if 0 then the attributs of sfpTemperature/sfpTranPower/sfpRecvPower 
								should be ignored"
				::= { mcCm1gSfpEntry 2 }

sfpConnector	OBJECT-TYPE
				SYNTAX			INTEGER
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"SFP connector type (one byte)
									0x01: SC
									0x07: LC
									0x22: RJ45
									others: unsupported"
				::= { mcCm1gSfpEntry 3 }

sfpTransCode	OBJECT-TYPE
				SYNTAX			INTEGER
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"SFP transceiver code (one byte)
									bit0: SingleMode
									bit2: MultiMode
									bit3: MultiMode
									others: unsupported"
				::= { mcCm1gSfpEntry 4 }

sfpSmLength		OBJECT-TYPE
				SYNTAX			INTEGER
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"SFP link length for SingleMode, units of km. (one byte)
								applicable only when sfpTransCode is SingleMode"
				::= { mcCm1gSfpEntry 5 }

sfpMmLength		OBJECT-TYPE
				SYNTAX			INTEGER
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"SFP link length for MultiMode, units of 10m (one byte)
								applicable only when sfpTransCode is MultiMode"
				::= { mcCm1gSfpEntry 6 }       
				
sfpCopperLength	OBJECT-TYPE
				SYNTAX			INTEGER
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"SFP link length for Copper, units of m (one byte)
								applicable only when sfpConnector is RJ45"
				::= { mcCm1gSfpEntry 7 }

sfpBrSpeed		OBJECT-TYPE
				SYNTAX			INTEGER
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"SFP nominal signalling rate, units of 100Mbit/s (one byte)"
				::= { mcCm1gSfpEntry 8 }   
				
sfpWavelength	OBJECT-TYPE
				SYNTAX			INTEGER
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"SFP laser wavelength (one word)"
				::= { mcCm1gSfpEntry 9 }

sfpTemperature	OBJECT-TYPE
				SYNTAX			INTEGER
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"SFP temperature (one type, signed)"
				::= { mcCm1gSfpEntry 10 }

sfpTranPower	OBJECT-TYPE
				SYNTAX			INTEGER
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"SFP tx power (one type, signed)"
				::= { mcCm1gSfpEntry 11 }

sfpRecvPower	OBJECT-TYPE
				SYNTAX			INTEGER
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"SFP rx power (one type, signed)"
				::= { mcCm1gSfpEntry 12 }

sfpVoltage		OBJECT-TYPE
				SYNTAX			INTEGER
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"SFP voltage, units of 0.1mV (one word)"
				::= { mcCm1gSfpEntry 13 }

-- --[MC Performance table] --
mcPmObjects		OBJECT IDENTIFIER ::= {cardObjects 3}

mcPmTable		OBJECT-TYPE
				SYNTAX			SEQUENCE OF McPmEntry
				MAX-ACCESS		not-accessible
				STATUS			current
				DESCRIPTION    "MC Performance table"
				::= { mcPmObjects 1 }			          

mcPmEntry		OBJECT-TYPE
				SYNTAX			McPmEntry
				MAX-ACCESS		not-accessible
				STATUS			current
				DESCRIPTION		"MC Performance entry definition"
				INDEX			{ mcShelfIdx, mcCardIdx }										  
						::= { mcPmTable 1 }
						
McPmEntry ::=		SEQUENCE {
					mcRxByteHi		Counter32,
					mcRxByteLo		Counter32,
					mcTxByteHi		Counter32,
					mcTxByteLo		Counter32,
					mcPmRest		INTEGER			
				}						
										  				
mcRxByteHi		OBJECT-TYPE
				SYNTAX			Counter32
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"The total number of reveive bytes (high)"
				::= { mcPmEntry 1 }          

mcRxByteLo		OBJECT-TYPE
				SYNTAX			Counter32
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"The total number of reveive bytes (low)"
				::= { mcPmEntry 2 } 				

mcTxByteHi		OBJECT-TYPE
				SYNTAX			Counter32
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"The total number of transmit bytes (high)"
				::= { mcPmEntry 3 }  
				 
mcTxByteLo		OBJECT-TYPE
				SYNTAX			Counter32
				MAX-ACCESS		read-only
				STATUS			current
				DESCRIPTION		"The total number of transmit bytes (low)"
				::= { mcPmEntry 4 }				               
								 
mcPmRest		OBJECT-TYPE
				SYNTAX			INTEGER  {idle(1), reset(2),not-support(3)}
				MAX-ACCESS		read-write
				STATUS			current
				DESCRIPTION		"reset counter"
				::= { mcPmEntry 5 }

-- ---------------------------------------------------------------------------------------------						
-- [Trap definition] --

-- --[shelf alarm] -- (1~19)       
shelf-Detected	NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx }
				STATUS  current                         
				DESCRIPTION   "A slave shelf is detected"
				::= { alarmMIB 1}
                        
shelf-Lost		NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx }
				STATUS  current                         
				DESCRIPTION   "A shelf is lost"
				::= { alarmMIB 2}            

shelf-psuA-On	NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx }
				STATUS  current                          
				DESCRIPTION   "PSU A is detected"
				::= { alarmMIB 3}   
 
shelf-psuA-Off	NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx }
				STATUS  current                          
				DESCRIPTION   "PSU A is lost"
				::= { alarmMIB 4}      

shelf-psuB-On	NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx }
				STATUS  current                          
				DESCRIPTION   "PSU B is detected"
				::= { alarmMIB 5}  

shelf-psuB-Off	NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx }
				STATUS  current                          
				DESCRIPTION   "PSU B is lost"
				::= { alarmMIB 6}  

shelf-fan-On	NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx }
				STATUS  current                          
				DESCRIPTION   "Fan A is detected"
				::= { alarmMIB 7}
						  
shelf-fan-Off	NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx }
				STATUS  current                         
				DESCRIPTION   "Fan A is lost"
				::= { alarmMIB 8}  

-- --[card common alarm] -- (20~29)
card-Detected	NOTIFICATION-TYPE 
				OBJECTS  { shelfIdx, slotIdx } 
				STATUS  current
				DESCRIPTION   "A card is detected"
				::= { alarmMIB 20} 

card-Lost		NOTIFICATION-TYPE
				OBJECTS  { shelfIdx, slotIdx }  
				STATUS  current     
				DESCRIPTION   "A card is lost"
				::= { alarmMIB 21}

-- --[card specific (MC) alarm] -- (above 30)
card-MC-Co-Tx-Up	NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx, slotIdx } 
				STATUS  current
				DESCRIPTION   "The tx link of mc in center side is up"
				::= { alarmMIB 30}
                            
card-MC-Co-Tx-Down	NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx, slotIdx }
				STATUS  current                                        
				DESCRIPTION   "The tx link of mc in center side is broken"
				::= { alarmMIB 31}
                                     
card-MC-Co-Fx-Up	NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx, slotIdx } 
				STATUS  current                                        
				DESCRIPTION   "The fx link of mc in center side is up"
				::= { alarmMIB 32}

card-MC-Co-Fx-Down	NOTIFICATION-TYPE                           
				OBJECTS  { shelfIdx, slotIdx }   
				STATUS  current                                        
				DESCRIPTION   "The fx link of mc in center side is broken"
				::= { alarmMIB 33}

card-MC-Rmt-Tx-Up	NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx, slotIdx }
				STATUS  current                                        
				DESCRIPTION   "The tx link of mc in customer side is up"
				::= { alarmMIB 34}
                         
card-MC-Rmt-Tx-Down	NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx, slotIdx }
				STATUS  current                                        
				DESCRIPTION   "The tx link of mc in customer side is broken"
				::= { alarmMIB 35}
                        
card-MC-Rmt-PwrDown	NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx, slotIdx }
				STATUS  current                                        
				DESCRIPTION   "Remote mc power down detected"
				::= { alarmMIB 36}

card-MC-Co-Ntw-SFP-Inserted	NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx, slotIdx }
				STATUS  current                                        
				DESCRIPTION   "Local network port SFP inserted"
				::= { alarmMIB 37}

card-MC-Co-Ntw-SFP-Removed	NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx, slotIdx }
				STATUS  current                                        
				DESCRIPTION   "Local network port SFP removed"
				::= { alarmMIB 38}

card-MC-Co-Acc-SFP-Inserted	NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx, slotIdx }
				STATUS  current                                        
				DESCRIPTION   "Local access port SFP inserted"
				::= { alarmMIB 39}

card-MC-Co-Acc-SFP-Removed	NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx, slotIdx }
				STATUS  current                                        
				DESCRIPTION   "Local access port SFP removed"
				::= { alarmMIB 40}

card-MC-Rmt-Acc-SFP-Inserted	NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx, slotIdx }
				STATUS  current                                        
				DESCRIPTION   "Remote access port SFP inserted"
				::= { alarmMIB 41}

card-MC-Rmt-Acc-SFP-Removed	NOTIFICATION-TYPE  
				OBJECTS  { shelfIdx, slotIdx }
				STATUS  current                                        
				DESCRIPTION   "Remote access port SFP removed"
				::= { alarmMIB 42}

END