-- MIB NAME     : HYTERA-REPEATER-MIB
-- LAST-UPDATED : 201402151323Z
-- REVISION     : 201402151323Z
-- ORGANIZATION : hytera
-- CONTACT-INFO :
-- DESCRIPTION  : 1. The MIB is for hytera repeater management based on SNMPv1.
--                2. The read community and write community are all set as public.
--                3. After setting an object, you should restart the repeater to make
--                   sure it works by setting the rptRestart object to 1.

HYTERA-REPEATER-MIB DEFINITIONS ::= BEGIN

IMPORTS
	private, enterprises, IpAddress, Counter, Gauge, TimeTicks
	    FROM RFC1155-SMI
	OBJECT-TYPE
	    FROM RFC-1212;

hyteraRepeaterMIB OBJECT IDENTIFIER
	-- 1.3.6.1.4.1.40297
	::= { enterprises 40297 }

product OBJECT IDENTIFIER
	-- 1.3.6.1.4.1.40297.1
	::= { hyteraRepeaterMIB 1 }

repeater OBJECT IDENTIFIER
	-- 1.3.6.1.4.1.40297.1.2
	::= { product 2 }


-- groups in repeater

rptRealTimeInfo OBJECT IDENTIFIER
	--1.3.6.1.4.1.40297.1.2.1
	::= { repeater 1 }
	
rptControl OBJECT IDENTIFIER
	--1.3.6.1.4.1.40297.1.2.2
	::= { repeater 2 }
	
rptLog OBJECT IDENTIFIER
	-- 1.3.6.1.4.1.40297.1.2.3
	::= { repeater 3 }
	
rptSystemInfo OBJECT IDENTIFIER
	--1.3.6.1.4.1.40297.1.2.4
	::= { repeater 4 }
	
rptConfiguration OBJECT IDENTIFIER
	--1.3.6.1.4.1.40297.1.2.5
	::= { repeater 5 }
	

-- the rptRealTimeInfo group

-- The rptRealTimeInfo group is consist of two sub groups, rptAlarmInfo group
-- and rptDataInfo group. The rptAlarmInfo group contains all the real time
-- alarm information of the repeater. The rptDataInfo group contains all the
-- real time data of the repeater.

rptAlarmInfo OBJECT IDENTIFIER
	--1.3.6.1.4.1.40297.1.2.1.1
	::= { rptRealTimeInfo 1 }

rptVoltageAlarm OBJECT-TYPE
	SYNTAX  INTEGER (0..2)			
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The voltage alarm.
		 normal(0), low voltage alarm(1), high voltage alarm(2), abnormal(3).
		 The abnormal condition is used for RD960. For the RD960 do not distinguish
		 low voltage alarm and high voltage alarm, we use abnormal to replace them."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.1.1.1
	::= { rptAlarmInfo 1 }

rptTemperatureAlarm OBJECT-TYPE				
	SYNTAX  INTEGER (0..2)
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The temperature alarm.
		 normal(0), low temperature alarm(1), high temperature alarm(2)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.1.1.2
	::= { rptAlarmInfo 2 }

rptFanAlarm OBJECT-TYPE
	SYNTAX  INTEGER (0..1)
	MAX-ACCESS read-only
	STATUS  optional
	DESCRIPTION
		"The fan alarm.
		 normal(0), alarm(1).
		 The object is not supported yet."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.1.1.3
	::= { rptAlarmInfo 3 }

rptForwardAlarm OBJECT-TYPE
	SYNTAX  INTEGER (-1..1)
	MAX-ACCESS read-only
	STATUS  optional
	DESCRIPTION
		"The forward power alarm.
		 undefined(-1), normal(0), alarm(1).
		 The object is not supported yet."
	DEFVAL { -1 }
	-- 1.3.6.1.4.1.40297.1.2.1.1.4
	::= { rptAlarmInfo 4 }

rptReflectedAlarm OBJECT-TYPE
	SYNTAX  INTEGER (-1..1)
	MAX-ACCESS read-only
	STATUS  optional
	DESCRIPTION
		"The reflected power alarm.
		 undefined(-1), normal(0), alarm(1).
		 The object is not supported yet."
	DEFVAL { -1 }
	-- 1.3.6.1.4.1.40297.1.2.1.1.5
	::= { rptAlarmInfo 5 }

rptVswrAlarm OBJECT-TYPE
	SYNTAX  INTEGER (0..1)
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The voltage standing wave radio alarm.
		 normal(0), alarm(1)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.1.1.6
	::= { rptAlarmInfo 6 }

rptTxPllAlarm OBJECT-TYPE
	SYNTAX  INTEGER (0..1)
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The transmitting PLL alarm.
		 normal(0), alarm(1)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.1.1.7
	::= { rptAlarmInfo 7 }

rptRxPllAlarm OBJECT-TYPE
	SYNTAX  INTEGER (0..1)
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The receiving PLL alarm.
		 normal(0), alarm(1)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.1.1.8
	::= { rptAlarmInfo 8 }

rptBatteryVoltageAlarm OBJECT-TYPE
	SYNTAX  INTEGER (0..2)
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The battery voltage alarm.
		 normal(0), abnormal(1)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.1.1.9
	::= { rptAlarmInfo 9 }

rptDataInfo OBJECT IDENTIFIER
	--1.3.6.1.4.1.40297.1.2.1.2
	::= { rptRealTimeInfo 2 }

rptVoltage OBJECT-TYPE
	SYNTAX  OCTET STRING(SIZE(4))
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The voltage.
		 It should be changed to float format.
		 If the repeater is rd620 and rd960, the value is invalid."
	-- 1.3.6.1.4.1.40297.1.2.1.2.1
	::= { rptDataInfo 1 }

rptPaTemprature OBJECT-TYPE
	SYNTAX  OCTET STRING(SIZE(4))
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The temperature.
		 It should be changed to float format.
		 The value is invalid, if the repeater is rd960."
	-- 1.3.6.1.4.1.40297.1.2.1.2.2
	::= { rptDataInfo 2 }

rptFanSpeed OBJECT-TYPE
	SYNTAX  INTEGER
	MAX-ACCESS read-only
	STATUS  optional
	DESCRIPTION
		"The fan speed.
		 The object is not supported yet."
	-- 1.3.6.1.4.1.40297.1.2.1.2.3
	::= { rptDataInfo 3 }

rptVswr OBJECT-TYPE
	SYNTAX  OCTET STRING(SIZE(4))
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The VSWR.
		 It should be changed to float format. "
	-- 1.3.6.1.4.1.40297.1.2.1.2.4
	::= { rptDataInfo 4 }

rptTxFwdPower OBJECT-TYPE
	SYNTAX  OCTET STRING(SIZE(4)) 		
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The forward power.
		 It should be changed to float format.
		 The value is invalid, if the repeater is rd960 or rd620."
	-- 1.3.6.1.4.1.40297.1.2.1.2.5
	::= { rptDataInfo 5 }

rptTxRefPower OBJECT-TYPE
	SYNTAX  OCTET STRING(SIZE(4))			
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The reflected power.
		 It should be changed to float format.
		 The value is invalid, if the repeater is rd960 or rd620."
	-- 1.3.6.1.4.1.40297.1.2.1.2.6
	::= { rptDataInfo 6 }

rptDataInfoBak1 OBJECT-TYPE
	SYNTAX  OCTET STRING(SIZE(4))			
	MAX-ACCESS read-only
	STATUS  optional
	DESCRIPTION
		"The backup object.
		 The object is not supported yet."
	-- 1.3.6.1.4.1.40297.1.2.1.2.7
	::= { rptDataInfo 7 }

rptDataInfoBak2 OBJECT-TYPE
	SYNTAX  OCTET STRING(SIZE(4)) 			
	MAX-ACCESS read-only
	STATUS  optional
	DESCRIPTION
		"The backup object.
		The object is not supported yet."
	-- 1.3.6.1.4.1.40297.1.2.1.2.8
	::= { rptDataInfo 8 }

rptSlot1Rssi OBJECT-TYPE
	SYNTAX  INTEGER 			
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The RSSI value of slot1.
		 unit: dB."
	DEFVAL { -200 }
	-- 1.3.6.1.4.1.40297.1.2.1.2.9
	::= { rptDataInfo 9 }

rptSlot2Rssi OBJECT-TYPE
	SYNTAX  INTEGER 			
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The RSSI value of slot2.
		 unit: dB.
		 The value is valid only in digital model."
	DEFVAL { -200 }
	-- 1.3.6.1.4.1.40297.1.2.1.2.10
	::= { rptDataInfo 10 }

rptSupplyPowerType OBJECT-TYPE
	SYNTAX  INTEGER 			
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The type of power.
		 DC(0), Battery(1)."
	-- 1.3.6.1.4.1.40297.1.2.1.2.11
	::= { rptDataInfo 11 }

rptBatteryConnect OBJECT-TYPE
	SYNTAX  INTEGER 			
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The battery connecting condition.
		 disconnected(0), connected(1)."
	-- 1.3.6.1.4.1.40297.1.2.1.2.12
	::= { rptDataInfo 12 }

rptBatteryVoltage OBJECT-TYPE
	SYNTAX  OCTET STRING(SIZE(4))			
	MAX-ACCESS read-only
	STATUS  optional
	DESCRIPTION
		"The battery voltage.
		 The object is not supported yet."
	-- 1.3.6.1.4.1.40297.1.2.1.2.13
	::= { rptDataInfo 13 }

-- the rptControl group

-- the rptControl group contains some basic control of the repeater, such as
-- repeater reseting, work channel switching and transmit power adjusting.
-- We can get some working information of the repeater also.
-- Some objects in this group is read-only, which may give some refrence for
-- controlling.

rptRestart OBJECT-TYPE
	SYNTAX  INTEGER (0..1)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"Restart the repeater.
		 do nothing(0), reset(1)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.2.1
	::= { rptControl 1 }

rptChannelNumber OBJECT-TYPE
	SYNTAX INTEGER (0..15)
	MAX-ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"The current channel number in the zone."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.2.2
	::= { rptControl 2 }

rptChannelType OBJECT-TYPE
	SYNTAX INTEGER (0..2)
	MAX-ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"The current channel type.
		 digital(0), analog(1), mixed(2)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.2.3
	::= { rptControl 3 }

rptControlObjBak1 OBJECT-TYPE
	SYNTAX INTEGER (0..1)
	MAX-ACCESS read-only
	STATUS optional
	DESCRIPTION
		"The backup object.
		 The object is not supported yet."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.2.4
	::= { rptControl 4 }

rptTxPowerLevel OBJECT-TYPE
	SYNTAX INTEGER (0|2)							
	MAX-ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"The transmit power level.
		 high(0), low(2)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.2.5
	::= { rptControl 5 }

rptKnockdown OBJECT-TYPE
	SYNTAX INTEGER (0..1)
	MAX-ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"The status of repeating.
		 repeating(0), knockdown(1)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.2.6
	::= { rptControl 6 }

rptRadioState OBJECT-TYPE
	SYNTAX INTEGER (0..1)			
	MAX-ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"The status of the repeater's normal function.
		 enable(0), disable(1)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.2.7
	::= { rptControl 7 }

rptSnmpTrapIp OBJECT-TYPE
  SYNTAX IpAddress
  MAX-ACCESS read-write
  STATUS mandatory
  DESCRIPTION
    "The SNMP trapping IP address.
     The default value is 230.37.0.0."
  -- 1.3.6.1.4.1.40297.1.2.2.8
  ::= { rptControl 8 }

rptSnmpTrapPort OBJECT-TYPE
  SYNTAX INTEGER (162)
  MAX-ACCESS read-only
  STATUS mandatory
  DESCRIPTION
    "The SNMP trapping port."
  DEFVAL { 162 }
  -- 1.3.6.1.4.1.40297.1.2.2.9
  ::= { rptControl 9 }

rptchannelParaTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF ChannelParaEntry
	MAX-ACCESS  not-accessible
	STATUS      mandatory
	DESCRIPTION
	  "The table of channel's parameters relevant to the repeater's channels."
  -- 1.3.6.1.4.1.40297.1.2.2.10
	::= { rptControl 10 }

channelParaEntry OBJECT-TYPE
	SYNTAX ChannelParaEntry
	MAX-ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
	  "The channel's parameters for one of the repeater's channels."
	INDEX { channelParaIndex  }
        -- 1.3.6.1.4.1.40297.1.2.2.10.1
	::= { rptchannelParaTable 1 }

ChannelParaEntry ::= SEQUENCE {
	channelParaIndex   INTEGER,
	actChannelAlias  OCTET STRING,
  actChannelType  INTEGER,		
	actTxPower   INTEGER,
	actChannelNo  INTEGER,
	actChannelSubNo  INTEGER
}

channelParaIndex OBJECT-TYPE
	SYNTAX INTEGER
	MAX-ACCESS read-only
	STATUS mandatory
	DESCRIPTION
	  "The index of the table which uniquely identifies the channel's parameters."
  -- 1.3.6.1.4.1.40297.1.2.2.10.1.1
	::= { channelParaEntry 1 }

actChannelAlias OBJECT-TYPE
	SYNTAX OCTET STRING (SIZE(32))
	MAX-ACCESS read-only
	STATUS mandatory
	DESCRIPTION
	  "The channel alias.
	   It is an unicode string"
  -- 1.3.6.1.4.1.40297.1.2.2.10.1.2
	::= { channelParaEntry 2 }

actChannelType  OBJECT-TYPE
	SYNTAX INTEGER
	MAX-ACCESS read-only
	STATUS mandatory
	DESCRIPTION
	  "The channel type.
	   digital(0), analog(1), mixed(2)."
  -- 1.3.6.1.4.1.40297.1.2.2.10.1.3
	::= { channelParaEntry 3 }
	
actTxPower  OBJECT-TYPE
	SYNTAX INTEGER
	MAX-ACCESS read-only
	STATUS mandatory
	DESCRIPTION
	  "The transmit power level.
	   high(0), low(2)."
  -- 1.3.6.1.4.1.40297.1.2.2.10.1.4
	::= { channelParaEntry 4 }
	
actChannelNo  OBJECT-TYPE
	SYNTAX INTEGER
	MAX-ACCESS read-only
	STATUS mandatory
	DESCRIPTION
	  "The channel number in the repeater's zone."
  -- 1.3.6.1.4.1.40297.1.2.2.10.1.5
	::= { channelParaEntry 5 }
	
actChannelSubNo  OBJECT-TYPE
	SYNTAX INTEGER
	MAX-ACCESS read-only
	STATUS mandatory
	DESCRIPTION
	  "The channel number in the group of same type."
  -- 1.3.6.1.4.1.40297.1.2.2.10.1.6
	::= { channelParaEntry 6 }

rptForbid OBJECT-TYPE
	SYNTAX INTEGER (0..1)			
	MAX-ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"The status of the repeater's all function.
		 nomal(0), forbid(1).
		 If the repeater is forbided, you can only wake up it by setting
		 the rptRadioStatus object to 0 in local RDAC model."
	-- 1.3.6.1.4.1.40297.1.2.2.11
	::= { rptControl 11 }
	
	
-- the rptLog group

-- The rptLog group contains all records of alarm in the history, include alarm
-- name, alarm status and alarm time. We can clear all records by setting the
-- clearLog object to 1.

logTable OBJECT-TYPE
	SYNTAX SEQUENCE OF LogEntry
	MAX-ACCESS  not-accessible
	STATUS      mandatory
	DESCRIPTION
	  "The table of alarm records."
	-- 1.3.6.1.4.1.40297.1.2.3.1
	::= { rptLog 1 }

logEntry OBJECT-TYPE
	SYNTAX LogEntry
	MAX-ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
	  "The record's content."
	INDEX { logIndex }
	-- 1.3.6.1.4.1.40297.1.2.3.1.1
	::= { logTable 1 }

LogEntry ::= SEQUENCE {
	logIndex INTEGER,
	alarmName INTEGER,		
	alarmStatus INTEGER,
	logTime INTEGER
}

logIndex OBJECT-TYPE
	SYNTAX INTEGER (1..100)
	MAX-ACCESS read-only
	STATUS mandatory
	DESCRIPTION
	  "The index of the table which uniquely identifies the alram record."
	-- 1.3.6.1.4.1.40297.1.2.3.1.1.1
	::= { logEntry 1 }

alarmName OBJECT-TYPE
	SYNTAX INTEGER (0..9|65535)
	MAX-ACCESS read-only
	STATUS mandatory
	DESCRIPTION
	  "The alarm name.
	   temperature alarm(0), fan alarm(1), vswr alarm(2), low forward power alarm(3),
     low voltage alarm(4), high voltage alarm(5), tx unlock alarm(6),
     rx unlock alarm(7), battery voltage alarm(8), invalid(65535)."
  DEFVAL { 65535 }
	-- 1.3.6.1.4.1.40297.1.2.3.1.1.2
	::= { logEntry 2 }

alarmStatus  OBJECT-TYPE
	SYNTAX INTEGER (0..1|65535)
	MAX-ACCESS read-only
	STATUS mandatory
	DESCRIPTION	
	  "The alarm status.
	   alarm recove(0), alarm happen(1), invalid(65535)."
  DEFVAL { 65535 }
	-- 1.3.6.1.4.1.40297.1.2.3.1.1.3
	::= { logEntry 3 }

logTime OBJECT-TYPE
	SYNTAX INTEGER (-1..134217728)
	MAX-ACCESS read-only
	STATUS mandatory
	DESCRIPTION
	  "The alarm time.
	   unit: second.
	   The time is the time lapsed since the repeater starting up. If the value
	   is -1, the record is invalid."
  DEFVAL { -1 }
	-- 1.3.6.1.4.1.40297.1.2.3.1.1.4
	::= { logEntry 4 }

clearLog OBJECT-TYPE
	SYNTAX INTEGER (0..1)
	MAX-ACCESS read-write
	STATUS	mandatory
	DESCRIPTION	
	  "Clear the log.
	   do nothing(0), clear log(0)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.3.2
	::= { rptLog 2 }

recordCount OBJECT-TYPE
	SYNTAX INTEGER (0..100)
	MAX-ACCESS read-only
	STATUS	mandatory
	DESCRIPTION	
	  "The number of records."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.3.3
	::= { rptLog 3 }

latestRecordPosition OBJECT-TYPE
	SYNTAX INTEGER (0..100)
	MAX-ACCESS read-only
	STATUS	mandatory
	DESCRIPTION	
	  "The row number of the latest record.
	   If the value is 0, there is no valid record in the table."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.3.4
	::= { rptLog 4 }
	
	
-- the rptSystemInfo group

-- The rptSystemInfo group contains repeater firmware and run-time system information.

rptModelName OBJECT-TYPE
	SYNTAX  OCTET STRING (SIZE(0..32))
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The model name.
		 It is an unicode string."
	-- 1.3.6.1.4.1.40297.1.2.4.1
	::= { rptSystemInfo 1 }

rptModelNo OBJECT-TYPE
	SYNTAX  OCTET STRING (SIZE(0..64))
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The model number.
		 It is an unicode string."
	-- 1.3.6.1.4.1.40297.1.2.4.2
	::= { rptSystemInfo 2 }

rptFirmwareVersion OBJECT-TYPE
	SYNTAX  OCTET STRING (SIZE(0..32))
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The firmware version.
		 It is an unicode string."
	-- 1.3.6.1.4.1.40297.1.2.4.3
	::= { rptSystemInfo 3 }

rptRcdbVersion OBJECT-TYPE
	SYNTAX  OCTET STRING (SIZE(0..32))
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The RCDB version.
		 It is an unicode string."
	-- 1.3.6.1.4.1.40297.1.2.4.4
	::= { rptSystemInfo 4 }

rptSerialNo OBJECT-TYPE
	SYNTAX  OCTET STRING (SIZE(0..32))
	MAX-ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"The serial number.
		 It is an unicode string."
	-- 1.3.6.1.4.1.40297.1.2.4.5
	::= { rptSystemInfo 5 }	

rptRadioAlias OBJECT-TYPE
	SYNTAX  OCTET STRING (SIZE(0..32))
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The repeater alias.
		 It is an unicode string."
	-- 1.3.6.1.4.1.40297.1.2.4.6
	::= { rptSystemInfo 6 }

rptRadioID OBJECT-TYPE
	SYNTAX  INTEGER
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The ID of the repeater."
	-- 1.3.6.1.4.1.40297.1.2.4.7
	::= { rptSystemInfo 7 }

rptCurChannelType OBJECT-TYPE
	SYNTAX  INTEGER (0..2)		
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The type of the wroking channel.
		 digital(0), analog(1), mixed(2)."
	-- 1.3.6.1.4.1.40297.1.2.4.8
	::= { rptSystemInfo 8 }

rptChannelName OBJECT-TYPE
	SYNTAX  OCTET STRING (SIZE(32))
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The name of the current channel.
		 It is an unicode string."
	-- 1.3.6.1.4.1.40297.1.2.4.9
	::= { rptSystemInfo 9 }

rptCurTxFreq OBJECT-TYPE
	SYNTAX  INTEGER (100000000..550000000)		
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The current transmitting frequency.
		 unit: Hz."
	-- 1.3.6.1.4.1.40297.1.2.4.10
	::= { rptSystemInfo 10 }

rptCurRxFreq OBJECT-TYPE
	SYNTAX  INTEGER (100000000..550000000)		
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The current receiving frequency.
		 unit: Hz."
	-- 1.3.6.1.4.1.40297.1.2.4.11
	::= { rptSystemInfo 11 }

rptWorkState OBJECT-TYPE
	SYNTAX  INTEGER		
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The work status of the repeater.
		 receive(0), transmit(1)."
	-- 1.3.6.1.4.1.40297.1.2.4.12
	::= { rptSystemInfo 12 }
	
rptCurZoneAlias OBJECT-TYPE
	SYNTAX  OCTET STRING (SIZE(32))
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The alias of the current zone.
		 It is an unicode string."
	-- 1.3.6.1.4.1.40297.1.2.4.13
	::= { rptSystemInfo 13 }
	
	
-- the rptConfiguration group

-- The rptConfiguration group is consist of four sub groups, rptBasicSetting
-- group, rptDigitalChannelSetting group, rptAnalogChannelSetting group,
-- rptMixedChannelSetting group and rptServiceSetting group. The rptBasicSetting
-- group contains some basic cofiguration parameters of the system. The
-- rptDigitalChannelSetting group contains some configuration parameters of the
-- digital channel. The rptAnalogChannelSetting group contains some configuration
-- parameters of the analog channel. The rptMixedChannelSetting group contains
-- some configuration parameters of the mixed channel. The rptServiceSetting group
-- contains some configuration parameters of the service.

rptBasicSetting OBJECT IDENTIFIER
	--1.3.6.1.4.1.40297.1.2.5.1
	::= { rptConfiguration 1 }

powerOn OBJECT IDENTIFIER
	--1.3.6.1.4.1.40297.1.2.5.1.1
	::= { rptBasicSetting 1 }

designatedPowerOnChn OBJECT-TYPE
        SYNTAX  INTEGER (0..1)			
        MAX-ACCESS read-write
        STATUS  mandatory
        DESCRIPTION
        "Designate the power on channel.
         disable(0), enable(1)."
        DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.1.1.1
	::= { powerOn 1 }

powerOnChannelNo OBJECT-TYPE
	SYNTAX  INTEGER (0..15|65535)				
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The the power on channel number.
		 invalid(65535)."
  DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.1.1.2
	::= { powerOn 2 }

microphone OBJECT IDENTIFIER
	-- 1.3.6.1.4.1.40297.1.2.5.1.2
	::= { rptBasicSetting 2 }

internalMicGain OBJECT-TYPE
	SYNTAX  INTEGER (4..36)			
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The gain of the internal microphone.
		 It is double of the real value."
	DEFVAL { 24 }
	-- 1.3.6.1.4.1.40297.1.2.5.1.2.1
	::= { microphone 1 }

externalMicGain OBJECT-TYPE
	SYNTAX  INTEGER (4..36)				
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The gain of the external microphone.
		 It is double of the real value."
	DEFVAL { 24 }
	-- 1.3.6.1.4.1.40297.1.2.5.1.2.2
	::= { microphone 2 }
	
multiCTCCDCTable OBJECT-TYPE
	SYNTAX SEQUENCE OF MultiCTCCDCEntry
	MAX-ACCESS  not-accessible
	STATUS mandatory
	DESCRIPTION
	"The table of subaudio frequency."
	-- 1.3.6.1.4.1.40297.1.2.5.1.3
	::= { rptBasicSetting 3 }

multiCTCCDCEntry OBJECT-TYPE
	SYNTAX MultiCTCCDCEntry
	MAX-ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
	"The subaudio frequency."
	INDEX { ctcssIndex }
	-- 1.3.6.1.4.1.40297.1.2.5.1.3.1
	::= { multiCTCCDCTable 1 }

MultiCTCCDCEntry ::= SEQUENCE {
	ctcssIndex INTEGER,
	txCtcssFrequency INTEGER,		
	txCtcssType INTEGER,
	rxCtcssFrequency INTEGER,
	rxCtcssType INTEGER
}

ctcssIndex OBJECT-TYPE
	SYNTAX INTEGER (1..16)
	MAX-ACCESS read-only
	STATUS mandatory
	DESCRIPTION
	"The index of the table which uniquely identifies the subaudio frequency."
	-- 1.3.6.1.4.1.40297.1.2.5.1.3.1.1
	::= { multiCTCCDCEntry 1 }

txCtcssFrequency OBJECT-TYPE
	SYNTAX INTEGER (0|19..492|670..2541)		
	MAX-ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"The transmitting subaudio frequency.
		 The value is limitted to the range. The range is changed with the type:
                 0        (txCtcssType: none)
                 19~492   (txCtcssType: CDCSS or CDCSS invert)
                 670~2541 (txCtcssType: CTCSS)
     The value is 10 times of the real value when the type is CTCSS.
     The value in first row is unable to be set.
     It's not able to be set, unless the rxCtcssType in the same row is not none.
     It will be set to the matched minimum available value automatically, when the
     txCtcssType in the same row is changed."
	-- 1.3.6.1.4.1.40297.1.2.5.1.3.1.2
	::= { multiCTCCDCEntry 2 }
	
txCtcssType OBJECT-TYPE
	SYNTAX INTEGER (0..3)				
	MAX-ACCESS read-write
	STATUS mandatory
	DESCRIPTION
	"The type of the transmitting subaudio frequency.
	 none(0), CTCSS(1), CDCSS(2), CDCSS invert(3).
	 The value in first row is unable to be set.
   It's not able to be set, unless the rxCtcssType in the same row is not none."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.1.3.1.3
	::= { multiCTCCDCEntry 3 }
	
rxCtcssFrequency OBJECT-TYPE
	SYNTAX INTEGER (0|19..492|670..2541)		
	MAX-ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"The receiving subaudio frequency.
		 The value is limitted to the range and is not allowed to duplicate but 0.
		 The range is changed with the type:0
                 0        (rxCtcssType: none)
                 19~492   (rxCtcssType: CDCSS or CDCSS invert)
                 670~2541 (rxCtcssType: CTCSS)
     The value is 10 times of the real value when the type is CTCSS.
     The value in first row is unable to be set.
     It will be set to the matched minimum available value automatically, when the
     rxCtcssType in the same row is changed."
	-- 1.3.6.1.4.1.40297.1.2.5.1.3.1.4
	::= { multiCTCCDCEntry 4 }
	
rxCtcssType OBJECT-TYPE
	SYNTAX INTEGER (0..3)		
	MAX-ACCESS read-write
	STATUS mandatory
	DESCRIPTION
	  "The type of the receiving subaudio frequency.
	   none(0), CTCSS(1), CDCSS(2), CDCSS invert(3).
	   It must be set according to line sequence.
     The value in first row is unable to be set."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.1.3.1.5
	::= { multiCTCCDCEntry 5 }

audioPriority OBJECT IDENTIFIER
	-- 1.3.6.1.4.1.40297.1.2.5.1.4
	::= { rptBasicSetting 4 }

pathPriority OBJECT-TYPE
	SYNTAX  INTEGER (0..2)				
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The transmit path priority.
		 PTT request(0), repeat request(1), first come first send(2)."
	DEFVAL { 1 }
	-- 1.3.6.1.4.1.40297.1.2.5.1.4.1
	::= { audioPriority 1 }

pttPriority OBJECT-TYPE
	SYNTAX  INTEGER (0..3)				
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The PTT priority.
		 external PTT(0), front PTT(1), remote PTT(2), first come first send(3)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.1.4.2
	::= { audioPriority 2 }

jitterBufferLenth OBJECT-TYPE			
	SYNTAX  INTEGER (1..8)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The jitter buffer length."
	DEFVAL { 1 }
	-- 1.3.6.1.4.1.40297.1.2.5.1.5
	::= { rptBasicSetting 5 }

analogCallHangTime OBJECT-TYPE		
	SYNTAX  INTEGER (0..70)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The analog call hang time.
		 unit: second."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.1.6
	::= { rptBasicSetting 6 }

repeatRequestPriority OBJECT-TYPE		
	SYNTAX  INTEGER (0..2)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The repeat request priority.
		 local repeating(0), IP connect repeating(1), first come first send(2)."
	DEFVAL { 2 }
	-- 1.3.6.1.4.1.40297.1.2.5.1.7
	::= { rptBasicSetting 7 }


rptDigitalChannelSetting OBJECT IDENTIFIER
	-- 1.3.6.1.4.1.40297.1.2.5.2	
	::= { rptConfiguration 2 }

digitalChnTable  OBJECT-TYPE
    SYNTAX  SEQUENCE OF DigitalChnEntry
    MAX-ACCESS  not-accessible
    STATUS  mandatory
	DESCRIPTION
		"The table of digital channel's configuration parameters relevant to the
		 repeater's digital channels."
	-- 1.3.6.1.4.1.40297.1.2.5.2.1
	::= { rptDigitalChannelSetting 1 }

digitalChnEntry  OBJECT-TYPE
	SYNTAX  DigitalChnEntry
	MAX-ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION
		"The digital channel's configuration parameters for one of the repeater's digital channels."
	INDEX { digitalChnIndex }
	-- 1.3.6.1.4.1.40297.1.2.5.2.1.1
	::= { digitalChnTable 1 }

DigitalChnEntry ::= SEQUENCE {
	digitalChnIndex  INTEGER,
	digitalColorCode  INTEGER,
	digitalIpMultisiteConnect  INTEGER,
	digitalReceiveFrequency  INTEGER,
	digitalTransmitFrequency  INTEGER,
	digitalTxContactName  INTEGER
}

digitalChnIndex  OBJECT-TYPE
	SYNTAX  INTEGER (1..16)
	MAX-ACCESS  read-only
	STATUS mandatory
	DESCRIPTION
		"The index of the table which uniquely identifies the digital channel's parameter.
		 It also represents the channel number which is counted from 1."
	-- 1.3.6.1.4.1.40297.1.2.5.2.1.1.1
	::= { digitalChnEntry 1 }	

digitalColorCode  OBJECT-TYPE
	SYNTAX  INTEGER (0..15)
	MAX-ACCESS  read-write
	STATUS mandatory
	DESCRIPTION
		"The color code."
	DEFVAL { 1 }
	-- 1.3.6.1.4.1.40297.1.2.5.2.1.1.2
	::= { digitalChnEntry 2 }

digitalIpMultisiteConnect  OBJECT-TYPE
	SYNTAX  INTEGER (0..3)				
	MAX-ACCESS  read-write
	STATUS mandatory
	DESCRIPTION
		"The multisite connecting based on network.
		 None(0), slot1(1), slot2(2), slot1&slot2(3)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.2.1.1.3
	::= { digitalChnEntry 3 }

digitalReceiveFrequency  OBJECT-TYPE
	SYNTAX  INTEGER (100000000..550000000)				
	MAX-ACCESS  read-write
	STATUS mandatory
	DESCRIPTION
		"The receiving frequency.
		 unit: Hz.
		 The value is limitted by the assigned frequency range and the last digit
		 should be 0 or 5."
	-- 1.3.6.1.4.1.40297.1.2.5.2.1.1.4
	::= { digitalChnEntry 4 }

digitalTransmitFrequency  OBJECT-TYPE
	SYNTAX  INTEGER (100000000..550000000)
	MAX-ACCESS  read-write
	STATUS mandatory
	DESCRIPTION
		"The transmitting frequency.
		 unit: Hz.
		 The value is limitted by the assigned frequency range and the last digit
		 should be 0 or 5."
	-- 1.3.6.1.4.1.40297.1.2.5.2.1.1.5
	::= { digitalChnEntry 5 }

digitalTxContactName  OBJECT-TYPE
	SYNTAX  INTEGER (0..512)
	MAX-ACCESS  read-write
	STATUS mandatory
	DESCRIPTION
		"The row number of transmitting contact name.
		 none(0), row number(1~512).
		 The value is limmited by the number of rows in contact table."
	-- 1.3.6.1.4.1.40297.1.2.5.2.1.1.6
	::= { digitalChnEntry 6 }

rptAnalogChannelSetting OBJECT IDENTIFIER
	-- 1.3.6.1.4.1.40297.1.2.5.3	
	::= { rptConfiguration 3 }

analogChnTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF AnalogChnEntry
        MAX-ACCESS  not-accessible
        STATUS  mandatory
	DESCRIPTION
		"The table of analog channel's configuration parameters relevant to the
		 repeater's analog channels."
	-- 1.3.6.1.4.1.40297.1.2.5.3.1
	::= { rptAnalogChannelSetting 1 }

analogChnEntry  OBJECT-TYPE
	SYNTAX  AnalogChnEntry
	MAX-ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION
		"The analog channel's configuration parameters for one of the repeater's analog channels."
	INDEX { analogChnIndex }
	-- 1.3.6.1.4.1.40297.1.2.5.3.1.1
	::= { analogChnTable 1 }

AnalogChnEntry ::= SEQUENCE {
	analogChnIndex  INTEGER,
	analogCarrierSquelchLevel  INTEGER,
	analogMultiCtcCdc  INTEGER,
	analogPreEmp  INTEGER,
	analogScrambler  INTEGER,
	analogFlatAudio  INTEGER,
	analogReceiveFrequency  INTEGER,
	analogRxCtcCdcType  INTEGER,
	analogRxCtcss  INTEGER,
	analogRxCdcss  INTEGER,
	analogTransmitFrequency  INTEGER,
	analogTxCtcCdcType  INTEGER,
	analogTxCtcss  INTEGER,
	analogTxCdcss  INTEGER
}

analogChnIndex  OBJECT-TYPE
	SYNTAX  INTEGER (1..16)		
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The index of the table which uniquely identifies the analog channel's parameters.
		 It also represents the channel number which is counted from 1."
	-- 1.3.6.1.4.1.40297.1.2.5.3.1.1.1
	::= { analogChnEntry  1 }

analogCarrierSquelchLevel OBJECT-TYPE
	SYNTAX  INTEGER (0..2)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The carrier squelch level.
		 open(0), normal(1), tight(2)"
	DEFVAL { 1 }
	-- 1.3.6.1.4.1.40297.1.2.5.3.1.1.2
	::= { analogChnEntry  2 }

analogMultiCtcCdc OBJECT-TYPE
	SYNTAX  INTEGER (0..1)		
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The multiCtcCdc control.
		 disable(0), enable(1).
		 It can't be set to enable until the analogRxCtcCdcType is not 0
		 and there is some valid data is multiCTCCDCTable."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.3.1.1.3
	::= { analogChnEntry  3 }

analogPreEmp OBJECT-TYPE
	SYNTAX  INTEGER (0..1)		
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The pre-emphasis control.
		 disable(0), enable(1)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.3.1.1.4
	::= { analogChnEntry  4 }

analogScrambler OBJECT-TYPE
	SYNTAX  INTEGER (0..1)	
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The scrambler control.
		 disable(0), enable(1)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.3.1.1.5
	::= { analogChnEntry  5 }

analogFlatAudio OBJECT-TYPE
	SYNTAX  INTEGER (0..1)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The flat audio control.
		 disable(0), enable(1)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.3.1.1.6
	::= { analogChnEntry  6 }

analogReceiveFrequency OBJECT-TYPE
	SYNTAX  INTEGER (100000000..550000000)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The receiving frequency.
		 unit: Hz.
		 The value is limitted by the assigned frequency range and the last digit
		 should be 0 or 5."
	-- 1.3.6.1.4.1.40297.1.2.5.3.1.1.7
	::= { analogChnEntry  7 }

analogRxCtcCdcType OBJECT-TYPE
	SYNTAX  INTEGER (0..3)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The type of receiving subaudio frequency.
		 none(0), CTCSS(1), CDCSS(2), CDCSS invert(3)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.3.1.1.8
	::= { analogChnEntry  8 }

analogRxCtcss OBJECT-TYPE
	SYNTAX  INTEGER (670..2541|65535)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The value of receiving CTCSS.
		 It's 10 times of the real value.
		 65535 is an invalid value.
		 The value is restricted by analogRxCtcCdcType."
	-- 1.3.6.1.4.1.40297.1.2.5.3.1.1.9
	::= { analogChnEntry  9 }

analogRxCdcss OBJECT-TYPE
	SYNTAX  INTEGER (19..492|65535)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The value of receiving CDCSS.
		 65535 is an invalid value.
		 The value is restricted by analogRxCtcCdcType."
	-- 1.3.6.1.4.1.40297.1.2.5.3.1.1.10
	::= { analogChnEntry  10 }

analogTransmitFrequency OBJECT-TYPE
	SYNTAX  INTEGER (100000000..550000000)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The transmitting frequency.
		 unit: Hz.
		 The value is limitted by the assigned frequency range and the last digit
		 should be 0 or 5."
	-- 1.3.6.1.4.1.40297.1.2.5.3.1.1.11
	::= { analogChnEntry  11 }

analogTxCtcCdcType OBJECT-TYPE
	SYNTAX  INTEGER (0..3)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The type of transmitting subaudio frequency.
		 none(0), CTCSS(1), CDCSS(2), CDCSS invert(3)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.3.1.1.12
	::= { analogChnEntry  12 }

analogTxCtcss OBJECT-TYPE
	SYNTAX  INTEGER (670..2541|65535)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The value of transmitting CTCSS.
		 It's 10 times of the real value.
		 65535 is an invalid value.
		 The value is limited by analogTxCtcCdcType."
	-- 1.3.6.1.4.1.40297.1.2.5.3.1.1.13
	::= { analogChnEntry  13 }

analogTxCdcss OBJECT-TYPE
	SYNTAX  INTEGER (19..492|65535)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The value of transmitting CDCSS.
		 65535 is an invalid value.
		 The value is restricted by analogTxCtcCdcType."
	-- 1.3.6.1.4.1.40297.1.2.5.3.1.1.14
	::= { analogChnEntry  14 }


rptMixedChannelSetting OBJECT IDENTIFIER
	-- 1.3.6.1.4.1.40297.1.2.5.4	
	::= { rptConfiguration 4 }

mixedChnTable  OBJECT-TYPE
    SYNTAX  SEQUENCE OF MixedChnEntry
    MAX-ACCESS  not-accessible
    STATUS  mandatory
	DESCRIPTION
		"The table of mixed channel's configuration parameters relevant to the
		 repeater's mixed channels."
	-- 1.3.6.1.4.1.40297.1.2.5.4.1
	::= { rptMixedChannelSetting 1 }

mixedChnEntry  OBJECT-TYPE
	SYNTAX  MixedChnEntry
	MAX-ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION
		"The mixed channel's configuration parameters for one of the repeater's mixed channels."
	INDEX { analogChnIndex }
	-- 1.3.6.1.4.1.40297.1.2.5.4.1.1
	::= { mixedChnTable  1 }

MixedChnEntry ::= SEQUENCE {
	mixedChnIndex  INTEGER,
	mixedCarrierSquelchLevel  INTEGER,
	mixedTxContactName INTEGER,
	mixedIpMultisiteConnect INTEGER,
	mixedColorCode INTEGER,
	mixedTxChannelType INTEGER,
	mixedPreEmp INTEGER,
	mixedScrambler INTEGER,
	mixedFlatAudio INTEGER,
	mixedMultiCtcCdc INTEGER,
	mixedReceiveFrequency INTEGER,
	mixedRxCtcCdcType INTEGER,
	mixedRxCtcss INTEGER,
	mixedRxCdcss INTEGER,
	mixedTransmitFrequency INTEGER,
	mixedTxCtcCdcType INTEGER,
	mixedTxCtcss INTEGER,
	mixedTxCdcss INTEGER
}

mixedChnIndex OBJECT-TYPE
	SYNTAX  INTEGER (1..16)		
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The index of the table which uniquely identifies the mixed channel's parameters.
		 It also represents the channel number which is counted from 1."
	-- 1.3.6.1.4.1.40297.1.2.5.4.1.1.1
	::= { mixedChnEntry  1 }

mixedCarrierSquelchLevel OBJECT-TYPE
	SYNTAX  INTEGER (0..2)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The carrier squelch level control.
		 open(0), normal(1), tight(2)."
	-- 1.3.6.1.4.1.40297.1.2.5.4.1.1.2
	::= { mixedChnEntry  2 }

mixedTxContactName OBJECT-TYPE
	SYNTAX  INTEGER (0..512)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The row number of transmitting contact name.
		 none(0), row number(1~512).
		 The value is limited to the numbers of row in the contact table."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.4.1.1.3
	::= { mixedChnEntry  3 }

mixedIpMultisiteConnect OBJECT-TYPE
	SYNTAX  INTEGER (0..3)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The multisite connecting based on network.
		 none(0), slot1(1), slot 2(2), slot1&slot2(3)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.4.1.1.4
	::= { mixedChnEntry  4 }

mixedColorCode OBJECT-TYPE
	SYNTAX  INTEGER (0..15)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The color code."
	DEFVAL { 1 }
	-- 1.3.6.1.4.1.40297.1.2.5.4.1.1.5
	::= { mixedChnEntry  5 }

mixedTxChannelType OBJECT-TYPE
	SYNTAX  INTEGER (0..1)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The type of transmitting channel.
		 digital(0), analog(1)."
	DEFVAL { 1 }
	-- 1.3.6.1.4.1.40297.1.2.5.4.1.1.6
	::= { mixedChnEntry  6 }

mixedPreEmp OBJECT-TYPE
	SYNTAX  INTEGER (0..1)		
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The pre-emphasis control.
		 disable(0), enable(1)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.4.1.1.7
	::= { mixedChnEntry  7 }

mixedScrambler OBJECT-TYPE
	SYNTAX  INTEGER (0..1)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The scrambler control.
		 disable(0), enable(1)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.4.1.1.8
	::= { mixedChnEntry  8 }

mixedFlatAudio OBJECT-TYPE
	SYNTAX  INTEGER (0..1)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The flat audio control.
		 disable(0), enable(1)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.4.1.1.9
	::= { mixedChnEntry  9 }

mixedMultiCtcCdc OBJECT-TYPE
	SYNTAX  INTEGER (0..1)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The multiCtcCdc control.
		 disable(0), enable(1).
		 It can't be set to enable until the mixedRxCtcCdcType is not 0
		 and there is some valid data in multiCTCCDC Table."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.4.1.1.10
	::= { mixedChnEntry  10 }

mixedReceiveFrequency OBJECT-TYPE
	SYNTAX  INTEGER (100000000..550000000)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The receiving frequency.
		 unit: Hz.
		 The value is limitted by the assigned frequency range and the last digit
		 should be 0 or 5."
	-- 1.3.6.1.4.1.40297.1.2.5.4.1.1.11
	::= { mixedChnEntry  11 }

mixedRxCtcCdcType OBJECT-TYPE
	SYNTAX  INTEGER (0..3)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The type of receiving subaudio frequency.
		 none(0), CTCSS(1), CDCSS(2), CDCSS invert(3)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.4.1.1.12
	::= { mixedChnEntry  12 }

mixedRxCtcss OBJECT-TYPE
	SYNTAX  INTEGER (670..2541|65535)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The value of receiving CTCSS.
		 It's 10 times of the real value.
		 65535 is an invalid value.
		 The value is restricted by analogRxCtcCdcType."
	-- 1.3.6.1.4.1.40297.1.2.5.4.1.1.13
	::= { mixedChnEntry  13 }

mixedRxCdcss OBJECT-TYPE
	SYNTAX  INTEGER (19..492|65535)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The value of receiving CDCSS.
		 65535 is an invalid value.
		 The value is restricted by analogRxCtcCdcType."
	-- 1.3.6.1.4.1.40297.1.2.5.4.1.1.14
	::= { mixedChnEntry  14 }

mixedTransmitFrequency OBJECT-TYPE
	SYNTAX  INTEGER (100000000..550000000)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The transmitting frequency.
		 unit: Hz.
		 The value is limitted by the assigned frequency range and the last digit
		 should be 0 or 5."
	-- 1.3.6.1.4.1.40297.1.2.5.4.1.1.15
	::= { mixedChnEntry  15 }

mixedTxCtcCdcType OBJECT-TYPE
	SYNTAX  INTEGER (0..3)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The type of transmitting subaudio frequency.
		 none(0), CTCSS(1), CDCSS(2), CDCSS invert(3)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.4.1.1.16
	::= { mixedChnEntry  16 }

mixedTxCtcss OBJECT-TYPE
	SYNTAX  INTEGER (670..2541|65535)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The value of transmitting CTCSS.
		 It's 10 times of the real value.
		 65535 is an invalid value.
		 The value is restricted by analogTxCtcCdcType."
	-- 1.3.6.1.4.1.40297.1.2.5.4.1.1.17
	::= { mixedChnEntry  17 }

mixedTxCdcss OBJECT-TYPE
	SYNTAX  INTEGER (19..492|65535)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The value of transmitting CDCSS.
		 65535 is an invalid value.
		 The value is restricted by analogTxCtcCdcType."
	-- 1.3.6.1.4.1.40297.1.2.5.4.1.1.18
	::= { mixedChnEntry  18 }


rptServiceSetting OBJECT IDENTIFIER
	-- 1.3.6.1.4.1.40297.1.2.5.5	
	::= { rptConfiguration 5 }

groupCallHangTime OBJECT-TYPE
	SYNTAX  INTEGER (0..60)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The group call hang time.
		 unit: second.
		 The value is 2 times of the real value and should not be greater than the
		 value of sit."
	DEFVAL { 6 }
	-- 1.3.6.1.4.1.40297.1.2.5.5.1
	::= { rptServiceSetting 1 }

privateCallHangTime OBJECT-TYPE
	SYNTAX  INTEGER (0..60)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The private call hang time.
		 unit: second.
		 The value is 2 times of the real value and should not be greater than the
		 value of sit."
	DEFVAL { 6 }
	-- 1.3.6.1.4.1.40297.1.2.5.5.2
	::= { rptServiceSetting 2 }

emergencyCallHangTime OBJECT-TYPE
	SYNTAX  INTEGER (0..60)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The emergency call hang time.
		 unit: second.
		 The value is 2 times of the real value and should not be greater than the
		 value of sit."
	DEFVAL { 8 }
	-- 1.3.6.1.4.1.40297.1.2.5.5.3
	::= { rptServiceSetting 3 }

sit OBJECT-TYPE
	SYNTAX  INTEGER (0|2..120)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The sit.
		 unit: second.
		 transmit always(0), the value of sit(2~120).
         The value is 2 times of the real value and should not be less than
         groupCallHangTime, privateCallHangTime and emergencyCallHangTime."
	DEFVAL { 12 }
	-- 1.3.6.1.4.1.40297.1.2.5.5.4
	::= { rptServiceSetting 4 }

txPreambleDuration OBJECT-TYPE
	SYNTAX  INTEGER (0..144)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The preamble duration.
		 unit: milisecond.
		 The value is 1/60 times of the real value."
	DEFVAL { 16 }
	-- 1.3.6.1.4.1.40297.1.2.5.5.5
	::= { rptServiceSetting 5 }

beaconTxMode OBJECT-TYPE
	SYNTAX  INTEGER (0..1)
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The beacon transmit mode.
		 local(0), network(1)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.5.6
	::= { rptServiceSetting 6 }

beaconDuration OBJECT-TYPE
	SYNTAX  INTEGER (0|4..150)	
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The beacon duration.
		 unit: milisecond.
		 disable(0), beacon duration(4~150).
		 The value is 1/120 times of the real value"
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.5.7
	::= { rptServiceSetting 7 }

beaconInterval OBJECT-TYPE
	SYNTAX  INTEGER (10..600)	
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The beacon interval.
		 unit: second."
	DEFVAL { 60 }
	-- 1.3.6.1.4.1.40297.1.2.5.5.8
	::= { rptServiceSetting 8 }

multisiteAccessManagement OBJECT-TYPE
	SYNTAX  INTEGER (0..1)	
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The multisite access management control.
		 disable(0), enable(1)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.5.9
	::= { rptServiceSetting 9 }

accessManagement OBJECT-TYPE
	SYNTAX  INTEGER (0..1)	
	MAX-ACCESS read-write
	STATUS  mandatory
	DESCRIPTION
		"The access management control.
		 disable(0), enable(1)."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.5.10
	::= { rptServiceSetting 10 }
	
multisiteAccessManageTable OBJECT-TYPE
	SYNTAX SEQUENCE OF MultisiteAccessManageEntry
	MAX-ACCESS  not-accessible
	STATUS      mandatory
	DESCRIPTION
	  "The table of multisite access management's parameters relevant to the
	   multisite access management."
	-- 1.3.6.1.4.1.40297.1.2.5.5.11
	::= { rptServiceSetting 11 }

multisiteAccessManageEntry OBJECT-TYPE
	SYNTAX MultisiteAccessManageEntry
	MAX-ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
	  "The multisite management parameters."
	INDEX { mutisiteAccessManageIndex  }
	-- 1.3.6.1.4.1.40297.1.2.5.5.11.1
	::= { multisiteAccessManageTable 1 }

MultisiteAccessManageEntry ::= SEQUENCE {
	multisiteAccessManageIndex  INTEGER,
	multisiteStartId  INTEGER,		
	multisiteIdLength  INTEGER,
	multisiteAccessCallType  INTEGER
}

multisiteAccessManageIndex OBJECT-TYPE
	SYNTAX INTEGER (1..32)
	MAX-ACCESS read-only
	STATUS mandatory
	DESCRIPTION
	  "The index of the table which uniquely identifies the multisite access
	   management's parameters."
	-- 1.3.6.1.4.1.40297.1.2.5.5.11.1.1
	::= { multisiteAccessManageEntry 1 }

multisiteStartId OBJECT-TYPE
	SYNTAX INTEGER (0..16776415)
	MAX-ACCESS read-write
	STATUS mandatory
	DESCRIPTION
	  "The start ID.
	   invalid record(0), start ID(1~16776415).
	   It can't be set until multisiteAccessManagement is enable and the previous
	   row is set. If it is set, the matched multisiteIdLength and
	   multisiteAccessCallType will be set to 100 and 1 automaticly."
	-- 1.3.6.1.4.1.40297.1.2.5.5.11.1.2
	::= { multisiteAccessManageEntry 2 }
	
multisiteIdLength OBJECT-TYPE
	SYNTAX INTEGER (1..255|65535)
	MAX-ACCESS read-write
	STATUS mandatory
	DESCRIPTION
	  "The ID length.
	   invalid(65535), ID length(1~255).
	   It can't be set until the multisiteAccessManagement is enable and the
	   matched multisiteStartId is set."
	-- 1.3.6.1.4.1.40297.1.2.5.5.11.1.3
	::= { multisiteAccessManageEntry 3 }
	
multisiteAccessCallType OBJECT-TYPE
	SYNTAX INTEGER (0..1|65535)
	MAX-ACCESS read-write
	STATUS mandatory
	DESCRIPTION
	  "The call type.
	   private call(0), group call(1), invalid(65535).
     It can't be set until multisiteAccessManagement is enable."
	DEFVAL { 1 }
	-- 1.3.6.1.4.1.40297.1.2.5.5.11.1.4
	::= { multisiteAccessManageEntry 4 }
	
contactTable OBJECT-TYPE
	SYNTAX SEQUENCE OF ContactEntry
	MAX-ACCESS  not-accessible
	STATUS      mandatory
	DESCRIPTION
	  "The table of contacts.
	   It is not allowed to add a new contact information."
	-- 1.3.6.1.4.1.40297.1.2.5.5.12
	::= { rptServiceSetting 12 }

contactEntry OBJECT-TYPE
	SYNTAX ContactEntry
	MAX-ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
	  "The contact information."
	INDEX { contactIndex }
	-- 1.3.6.1.4.1.40297.1.2.5.5.12.1
	::= { contactTable 1 }

ContactEntry ::= SEQUENCE {
	contactIndex  INTEGER,
	callAlias  OCTET STRING,
  contactCallType INTEGER,		
	callId  INTEGER
}

contactIndex OBJECT-TYPE
	SYNTAX INTEGER (1..512)
	MAX-ACCESS read-only
	STATUS mandatory
	DESCRIPTION
	  "The index of the table which uniquely identifies the contact information."
	-- 1.3.6.1.4.1.40297.1.2.5.5.12.1.1
	::= { contactEntry 1 }

callAlias OBJECT-TYPE
	SYNTAX OCTET STRING (SIZE(32))
	MAX-ACCESS read-write
	STATUS mandatory
	DESCRIPTION
	  "The call alias.
	   It is an unicode string.
	   The value should be exclusive."
	-- 1.3.6.1.4.1.40297.1.2.5.5.12.1.2
	::= { contactEntry 2 }

contactCallType OBJECT-TYPE
	SYNTAX INTEGER (0..2|65535)
	MAX-ACCESS read-write
	STATUS mandatory
	DESCRIPTION
	  "The call type.
	   private call(0), group call(1), all call(2), invalid(65535).
     If the contactCallType is all call, the matched callId will be set to
     16777215 automatically. The number of all call contact must be less than 2."
	DEFVAL { 1 }
	-- 1.3.6.1.4.1.40297.1.2.5.5.12.1.3
	::= { contactEntry 3 }
	
callId OBJECT-TYPE
	SYNTAX INTEGER (0..16776415|16777215)
	MAX-ACCESS read-write
	STATUS mandatory
	DESCRIPTION
	  "The call ID.
	   invalid(0), call ID(1~16776415,16777215).
	   The callId should be exclusive in the group of same call type."
	-- 1.3.6.1.4.1.40297.1.2.5.5.12.1.4
	::= { contactEntry 4 }
	
accessManageTable OBJECT-TYPE
	SYNTAX SEQUENCE OF AccessManageEntry
	MAX-ACCESS  not-accessible
	STATUS      mandatory
	DESCRIPTION
	  "The table of access management's parameters relevant to the access management."
	-- 1.3.6.1.4.1.40297.1.2.5.5.13
	::= { rptServiceSetting 13 }

accessManageEntry OBJECT-TYPE
	SYNTAX AccessManageEntry
	MAX-ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
	  "The access management parameters."
	INDEX { accessManageIndex  }
	-- 1.3.6.1.4.1.40297.1.2.5.5.13.1
	::= { accessManageTable 1 }

AccessManageEntry ::= SEQUENCE {
	accessManageIndex  INTEGER,
	startId  INTEGER,		
	idLength  INTEGER
}

accessManageIndex OBJECT-TYPE
	SYNTAX INTEGER (1..32)
	MAX-ACCESS read-only
	STATUS mandatory
	DESCRIPTION
	  "The index of the table which uniquely identifies the access management's
	   parameters."
	-- 1.3.6.1.4.1.40297.1.2.5.5.13.1.1
	::= { accessManageEntry 1 }

startId OBJECT-TYPE
	SYNTAX INTEGER (0..16776415)
	MAX-ACCESS read-write
	STATUS mandatory
	DESCRIPTION
	  "The start ID.
	   invalid record(0), start ID(1~16776415).
	   It can't be set until accessManagement is enable and the previous
	   row is set. If it is set, the matched idLength will be set to 100
	   automaticly."
	-- 1.3.6.1.4.1.40297.1.2.5.5.13.1.2
	::= { accessManageEntry 2 }
	
idLength OBJECT-TYPE
	SYNTAX INTEGER (1..255|65535)
	MAX-ACCESS read-write
	STATUS mandatory
	DESCRIPTION
	  "The ID length.
	   invalid(65535), ID length(1~255).
	   It can't be set until the accessManagement is enable and the
	   matched startId is set."
	-- 1.3.6.1.4.1.40297.1.2.5.5.13.1.3
	::= { accessManageEntry 3 }

repeatTOTTime OBJECT-TYPE
	SYNTAX  INTEGER (0|3..120)	
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The repeat TOT time.
		 unit: second.
		 The value is 1/5 times of the real value."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.40297.1.2.5.5.14
	::= { rptServiceSetting 14 }

rerepeatTOTTime OBJECT-TYPE
	SYNTAX  INTEGER (1..60)	
	MAX-ACCESS read-only
	STATUS  mandatory
	DESCRIPTION
		"The rerepeat TOT time.
		 unit: second."
	DEFVAL { 5 }
	-- 1.3.6.1.4.1.40297.1.2.5.5.15
	::= { rptServiceSetting 15 }

END